High-viscosity rotor pumps are a new type of positive-displacement pump developed to meet the needs of industries such as petroleum, chemical processing, coatings, lubricants, pharmaceuticals, dyes, and food. Thanks to their ability to be configured with various materials and designs, these pumps are widely used for conveying fluids of differing properties and viscosities. If the flushing fluid supply is unexpectedly insufficient or interrupted, the check valve automatically closes, allowing the friction ring to bear the fluid load at the sealing end and thereby preventing the sealed medium from entering the sealing chamber, thus providing protection for the seal. 1. Use the high-viscosity rotor pump only at its specified voltage; ensure that the line voltage remains within ±10% of the voltage indicated on the pump’s nameplate. 2. After unpacking the high-viscosity rotor pump, connect it to the motor and securely fasten the coupling to integrate the pump body and motor into a single unit. Then, properly attach the discharge piping. 3. Before operation, inspect all components to confirm they are in good condition before starting the pump. 4. Do not run the high-viscosity rotor pump under no-load conditions. Once pumping is complete, stop the pump immediately; otherwise, wear on the impeller seals, bearings, and other parts may accelerate, and the pump tubing could also suffer damage. 5. Replace the carbon brushes promptly when they become worn to the point where they can no longer function effectively. Both brushes should be replaced simultaneously; otherwise, poor contact between the brushes and the commutator may cause damage to the commutator, and in severe cases, even burn out the armature. 6. The high-viscosity rotor pump must not be operated under any of the following conditions: if insulation damage, cracks in the power cord or cable jacket, fractures or poor contact in plugs or sockets, intermittent operation, sparking, or other malfunctions are detected during use. In such cases, the motor housing must be repaired immediately; do not operate until repairs are completed. 7. Prevent overloading of the high-viscosity rotor pump. If abnormal speeds or reduced performance occur, stop the pump immediately to check for obstructions lodged in the impeller or potential motor malfunctions. If the pump suddenly stalls, disconnect the power supply without delay. 8. Handle all tools and equipment associated with the high-viscosity rotor pump with care; handle all pumps gently to avoid impacts or shocks. A high-viscosity rotor pump is a mechanical device used to convey fluids or increase fluid pressure. It transfers mechanical energy from the prime mover or other external sources to the liquid, thereby increasing the fluid’s energy. The pump mainly consists of gears, a shaft, a pump housing, a relief valve, and an end-face seal. The rotor undergoes heat treatment to achieve high hardness and strength and operates within a replaceable sleeve mounted on the shaft. All internal components are automatically lubricated during operation by the pumped fluid itself. The pump features well-designed oil‑drain and return channels, which reduce the torque experienced by the gears during operation, resulting in lower bearing loads, reduced wear, and higher efficiency. A control valve serves as overload protection; the relief valve’s full‑flow backpressure is set at 1.5 times the pump’s rated discharge pressure, though it can be further adjusted within the allowable discharge pressure range according to actual requirements. However, note that this control valve should not be used long-term as a pressure‑reducing valve; if needed, an additional pressure‑reducing device can be installed separately on the pipeline.
The high-viscosity rotor pump is a new type of positive-displacement pump developed to meet the needs of industries such as petroleum, chemical engineering, coatings, lubricants, pharmaceuticals, dyes, and food processing. Thanks to its ability to be configured with various materials and designs, it is widely used for conveying media of differing properties and viscosities. In the event of an occasional shortage or interruption of flushing fluid, the check valve automatically closes, allowing the friction ring to bear the fluid load at the sealing end and thereby preventing the sealed medium from entering the seal chamber, thus providing protection for the seal.
1. High-viscosity rotary pumps must be operated at the specified voltage; the supply voltage shall not deviate by more than ±10% from the rated voltage indicated on the pump’s nameplate.
2. After unpacking the high-viscosity rotor pump, connect it to the electric motor and securely fasten the coupling to integrate the pump body and motor into a single unit; then properly install the discharge piping.
3. Before operating a high-viscosity rotor pump, verify that all components are in good condition and free from damage before starting the equipment.
4. High-viscosity rotor pumps should not be run dry. During operation, stop the pump immediately after suction is complete; otherwise, wear on the impeller seals and bearings will accelerate, and the pump piping may also be damaged.
5. For high-viscosity rotor pumps, replace the carbon brushes promptly. When the brushes are worn to the point where they can no longer be used, they must be replaced immediately (both brushes should be replaced at the same time); otherwise, poor contact between the brushes and the commutator may lead to damage, resulting in commutator failure and, in severe cases, burning out the armature.
6. High-viscosity rotor pumps shall not be used under the following conditions. During operation, if insulation damage, cracking of the power cord or cable sheath, cracks in the plug or socket, poor contact, intermittent operation, sparking, or other malfunctions are detected, the equipment must be repaired immediately. It must not be used until it has been properly repaired.
7. High-viscosity rotor pumps are designed to prevent overload. During operation, if the rotational speed becomes abnormal or drops, immediately stop the pump and inspect for foreign objects jamming the impeller or for any motor malfunctions. If the pump is braked for any reason, disconnect the power supply without delay.
8. Handle tools for high-viscosity rotor pumps with care; all rotary pumps should be handled gently to avoid impact.
A high-viscosity rotor pump is a machine used to convey fluids or to increase their pressure. It transfers mechanical energy from the prime mover or other external sources to the fluid, thereby increasing the fluid’s energy. The pump primarily consists of gears, shafts, a pump housing, a relief valve, and shaft-end seals. The rotors undergo heat treatment to achieve high hardness and strength and are mounted together with the shafts within replaceable bushings that allow for smooth operation. All internal components are automatically lubricated during operation by the pumped medium itself. The pump features well‑designed drain and return oil channels, which reduce the torque experienced by the gears during operation, resulting in lower bearing loads, reduced wear, and higher pump efficiency. A control valve is provided as overload protection; the relief valve’s full‑flow back‑pressure is set at 1.5 times the pump’s rated discharge pressure, though it can be adjusted within the allowable discharge pressure range according to actual requirements. However, this control valve should not be used as a pressure‑reducing valve for continuous operation; if needed, an additional pressure‑reducing device may be installed on the pipeline.