Regular maintenance of horizontal double-suction pumps
Horizontal Double-Suction Pump: How to Perform Regular Pump Maintenance? I. Purpose of Pump Maintenance: To ensure the pump remains in excellent operating or standby condition at all times. II. Pump Maintenance Tasks: 1. Inspect the Stuffing Box When using a stuffing box seal, pay close attention to its tightness. If too loose, excessive leakage will impair performance; under normal conditions, leakage should be around sixty drops per minute—dripping is acceptable, but excessive dripping indicates a problem. 2. Inspect the Mechanical Seal The mechanical seal should show no visible leakage. If you notice any dripping from the seal, replace it immediately. 3. Lubricate the Bearings Check the oil for discoloration or contamination; if present, replace it promptly. If abnormal bearing noises are detected, the bearings must be replaced. 4. Check the Oil Tank Verify that the oil level is adequate; if low, top up to the proper level. 5. Inspect and Clean the Impeller If foreign objects have entered the impeller, inspect and clean it thoroughly to keep the flow passages unobstructed. Any wear on the impeller can reduce flow rate and head efficiency, necessitating replacement. 6. Examine Wear Parts Regularly check vulnerable components and replace them as needed to maintain pump efficiency. 7. Replace Damaged Coupling Bolts and Rubber Gaskets 8. Tighten Base Mounting Screws and Apply Anti-Rust Treatment. III. Motor Maintenance 1. Ensure the motor’s exterior is clean, the nameplate intact, and the grounding wire securely connected. 2. Remove the terminal blocks inside the motor junction box and use a 500V megohmmeter to measure insulation resistance between phases and between each phase and ground; the reading should not be less than 0.5 MΩ. 3. Verify that the three-phase leads and terminal blocks within the junction box are firmly and tightly secured. IV. Maintenance of Valves, Piping, and Accessories 1. All valves should operate smoothly and reliably, with no internal or external leaks. 2. Check that check valves function flexibly and exhibit no water leakage on either side. 3. Pressure gauges must provide accurate readings with clear dials. 4. Pipes and accessories should have clean, attractive exteriors free of cracks, with paint intact and undamaged. 5. Perform a jog test to confirm correct pump rotation direction; if incorrect, make the necessary adjustments. V. Control Cabinet Maintenance 1. Disconnect the main power supply to the control cabinet and verify that all transfer switches, start buttons, and stop buttons operate smoothly and reliably. 2. Inspect the internal circuit breakers, contactors, relays, and other electrical components for proper condition, and tighten all connection screws on terminals and wiring connections. 3. Clean dust from both the interior and exterior of the cabinet. 4. Reconnect the main power supply and confirm that the power indicator displays normal operation. 5. After maintenance, energize the pump and observe whether the ammeter and indicator lights function correctly. 6. Ensure the pump runs smoothly, without noticeable vibration or unusual noises, that the pressure gauge reads normally, and that all electrical components in the control cabinet remain quiet.
View Details >
Causes of Leakage in Screw Pumps and Precautions
There are several reasons why a screw pump may suddenly leak during normal operation: first, mechanical seal leakage; second, misalignment during installation; and third, wear of the shaft sleeve. The pump’s casing and liner are integrated into a single unit (collectively referred to as the pump body), with a mechanical seal serving as the shaft seal. Screw pumps come in various structural designs, typically handling small flow rates ranging from 0.2 to 6.5 m³/h. As mentioned earlier, the pump body and liner are combined into one piece, and the shaft seal is a mechanical type. The fluid being pumped moves axially in a uniform straight line within the pump, resulting in low pressure pulsation, stable flow, and reduced noise. Additionally, due to the low inertia of rotating components, the starting torque and vibration are minimal. The main causes of sudden leakage during normal operation include: cavitation, air entrainment, or prolonged pressure buildup, which can damage the seals; insufficient actual output leading to excessive internal recirculation of the medium, causing heat accumulation and subsequent vaporization that compromises the seal; excessive backflow, which stirs up sediment at the bottom of the suction-side vessel (such as a tower, kettle, tank, or pool), thereby damaging the seal; and failure to manually turn the pump by hand before restarting after extended downtime, resulting in adhesion between friction pairs and tearing of the sealing surfaces. During operation, because the two driven screws symmetrically mesh with the driving screw, all radial forces acting on the driving screw are balanced, so it does not experience bending loads. The radial forces on the driven screws are supported along their entire length by the pump cylinder liner, eliminating the need for additional bearings at the ends and virtually removing bending stresses. Furthermore, during operation, an oil film forms between the outer surface of the screws and the inner wall of the pump cylinder, preventing direct metal-to-metal contact and significantly reducing wear on the screw tooth surfaces. What aspects should be understood when using a screw pump? 1. Downhole gas separation: Ineffective pump performance is often caused by gas interference, which can be diagnosed through acoustic liquid‑level measurements and dynamometer cards. Ideally, the pump inlet should be positioned below the fluid entry zone; if placed above, a gas separator must be used. If the valve seat section is installed at least 10 feet below the bottom of the fluid entry zone, effective gas separation can occur in the annulus, with the casing functioning as the outer shell of the separator. However, well conditions frequently preclude positioning the pump below the fluid entry zone, necessitating the use of a downhole gas separator. Conventional gas separators consist of a fluid entry section (e.g., a perforated tubing section), an outer tube (typically a capped tubing section at the bottom), and a liquid‑sealing pipe at the pump base. 2. Diagnosing low‑energy effects: To diagnose this issue, determine the overall efficiency of the pumping system by measuring the input power of the prime mover, assessing the bottomhole production pressure, and collecting accurate production test data. For conventional beam‑type pumping systems, the total efficiency should ideally be around 50%; if lower, performance needs improvement. Techniques to enhance overall efficiency include maintaining high volumetric efficiency—matching pump specifications to wellbore injection rates, mitigating gas interference, and employing vacuum controllers or timers to regulate pumping—and replacing oversized electric motors. 3. Dynamometer cards measure the pump’s fill factor percentage, while integrated data acquisition systems can simultaneously capture motor power and dynamometer readings. One primary purpose of dynamometer cards is to diagnose pump operating conditions and analyze downhole issues. Combining liquid‑level measurements with dynamometer data helps determine whether the well is producing at high rates, whether the liquid column exceeds the depth of the pump inlet, whether the pump is not fully filled, and whether free gas is migrating upward through the annulus. 4. Pump displacement can be controlled by adjusting four parameters: plunger size, stroke length, pump strokes per minute, and daily operating hours. Since replacing equipment is costly, it is usually preferable to modify existing configurations rather than changing pump dimensions. A simpler approach involves reconfiguring surface equipment—for example, moving the beam linkage to alter the stroke length of both the surface and pump mechanisms—or replacing the motor pulley to adjust the number of pump strokes. Matching pump capacity to well productivity can also be achieved by modifying daily operating hours. Several devices can help control operating time, including vacuum controllers, interval timers, and percentage‑based timers. Vacuum controllers stop the pump if they detect incomplete filling, while interval timers offer a cost‑effective and easy‑to‑operate solution. The duration of pump shutdowns should be kept short enough to ensure that the bottomhole production pressure rises by no more than 10% of the reservoir pressure. Operators can allocate approximately 45 minutes per well to perform acoustic and dynamometer measurements, thereby determining well productivity, downhole pump dynamics, downhole gas separator performance, sucker rod and beam‑type pumping machine loadings, and motor status. Through this 45‑minute analysis, operators can maximize well output while reducing operational costs. 5. Acoustic liquid‑level measurements should be conducted to determine the relative depth between the liquid level and the pump inlet. If the liquid level exceeds the pump inlet, the well cannot sustain high production rates. When gas interference affects yield, the liquid level will be higher than the pump inlet; conversely, if excessive pumping leads to low production, the liquid level should be at or near the pump inlet.
How should a high-viscosity rotor pump be used correctly?
High-viscosity rotor pumps are a new type of positive-displacement pump developed to meet the needs of industries such as petroleum, chemical processing, coatings, lubricants, pharmaceuticals, dyes, and food. Thanks to their ability to be configured with various materials and designs, these pumps are widely used for conveying fluids of differing properties and viscosities. If the flushing fluid supply is unexpectedly insufficient or interrupted, the check valve automatically closes, allowing the friction ring to bear the fluid load at the sealing end and thereby preventing the sealed medium from entering the sealing chamber, thus providing protection for the seal. 1. Use the high-viscosity rotor pump only at its specified voltage; ensure that the line voltage remains within ±10% of the voltage indicated on the pump’s nameplate. 2. After unpacking the high-viscosity rotor pump, connect it to the motor and securely fasten the coupling to integrate the pump body and motor into a single unit. Then, properly attach the discharge piping. 3. Before operation, inspect all components to confirm they are in good condition before starting the pump. 4. Do not run the high-viscosity rotor pump under no-load conditions. Once pumping is complete, stop the pump immediately; otherwise, wear on the impeller seals, bearings, and other parts may accelerate, and the pump tubing could also suffer damage. 5. Replace the carbon brushes promptly when they become worn to the point where they can no longer function effectively. Both brushes should be replaced simultaneously; otherwise, poor contact between the brushes and the commutator may cause damage to the commutator, and in severe cases, even burn out the armature. 6. The high-viscosity rotor pump must not be operated under any of the following conditions: if insulation damage, cracks in the power cord or cable jacket, fractures or poor contact in plugs or sockets, intermittent operation, sparking, or other malfunctions are detected during use. In such cases, the motor housing must be repaired immediately; do not operate until repairs are completed. 7. Prevent overloading of the high-viscosity rotor pump. If abnormal speeds or reduced performance occur, stop the pump immediately to check for obstructions lodged in the impeller or potential motor malfunctions. If the pump suddenly stalls, disconnect the power supply without delay. 8. Handle all tools and equipment associated with the high-viscosity rotor pump with care; handle all pumps gently to avoid impacts or shocks. A high-viscosity rotor pump is a mechanical device used to convey fluids or increase fluid pressure. It transfers mechanical energy from the prime mover or other external sources to the liquid, thereby increasing the fluid’s energy. The pump mainly consists of gears, a shaft, a pump housing, a relief valve, and an end-face seal. The rotor undergoes heat treatment to achieve high hardness and strength and operates within a replaceable sleeve mounted on the shaft. All internal components are automatically lubricated during operation by the pumped fluid itself. The pump features well-designed oil‑drain and return channels, which reduce the torque experienced by the gears during operation, resulting in lower bearing loads, reduced wear, and higher efficiency. A control valve serves as overload protection; the relief valve’s full‑flow backpressure is set at 1.5 times the pump’s rated discharge pressure, though it can be further adjusted within the allowable discharge pressure range according to actual requirements. However, note that this control valve should not be used long-term as a pressure‑reducing valve; if needed, an additional pressure‑reducing device can be installed separately on the pipeline.
Maintenance of single-screw pumps?
A single‑screw pump mainly consists of an inlet body, an outlet body, a stator and rotor, a universal joint, a drive shaft, an intermediate shaft, and other components. Sealing options include packing seals and mechanical seals, while drive methods comprise direct motor drive and belt‑driven operation. Proper maintenance of a single‑screw pump—covering startup, operation, and shutdown—is essential to prolong its service life. I. Pre‑startup Maintenance: 1. Ensure that both the inlet and outlet valves are fully open. 2. For first-time startup or when restarting a pump that has been stored for an extended period, verify that the pump chamber is empty of fluid; fill the inlet chamber with an appropriate amount of the conveyed medium to prevent dry running. 3. A slight drip at the shaft seal is normal; however, if leakage increases significantly, stop the pump, repair the mechanical seal, and then restart. 4. When cleaning pipelines with high‑temperature steam, avoid allowing the steam to pass through the pump. 5. Inspect the coupling connection of the single‑screw pump for misalignment; if any deviation is detected, promptly adjust the coupling’s coaxiality. II. In‑operation Maintenance: 1. After starting the pump, closely monitor the ammeter, pressure gauge, and vacuum gauge readings. If any reading exceeds the specified limits, stop the pump, identify the cause, and restart only after resolving the issue. 2. During operation, if abnormal vibration or noise occurs, immediately shut down the pump to address the problem and prevent excessive vibration from damaging the pump assembly. 3. Begin operation with a brief jog test; only proceed to continuous running once no issues are observed. III. Post‑shutdown Maintenance: 1. If the single‑screw pump will remain idle for an extended period, apply an oil seal and periodically inspect its condition; reapply the seal as necessary. 2. When the pump is not in use, lubricate all moving parts with an appropriate amount of oil, and avoid exposing it to direct sunlight or humid environments to prevent long-term degradation and deformation of the stator components.
Winter Antifreeze and Thawing Measures for Water Pumps in Northern Regions
Recently, some motor companies have reported strong results in their semi-annual reports and performance forecasts. For instance, Zhongdian Motor achieved operating revenue of RMB 201.4216 million in the first half of 2018, up 48.06% year-on-year, with a net profit of RMB 26.4757 million, an increase of 49.01% compared to the same period last year, fulfilling 63.02% of its annual target. Meanwhile, Dayang Motor disclosed its third-quarter earnings forecast, projecting a net profit for the first three quarters ranging from RMB 138.5552 million to RMB 245.1361 million—a year-over-year change between -35% and +15%. According to the company’s announcement, since 2018, the new-energy vehicle industry has maintained robust growth momentum. As winter approaches, cold air and low temperatures can easily cause water pumps to freeze, potentially leading to damage or even rupture of the pump housing. To prevent such issues, the following measures are recommended: 1. Insulate exposed parts of the pump, pipes, and faucets using materials like cotton wool, towels, or old clothing to retain heat. 2. Drain any unused water from the pump to avoid freezing and subsequent cracking. 3. Ensure that basement pump rooms—whether equipped with heating systems or not—are kept tightly sealed; unfinished basement pump rooms should have all ventilation openings properly blocked. 4. If equipment is temporarily out of service, implement effective drainage measures to prevent freezing and potential damage. 5. Should a pump freeze, do not attempt to start it immediately. Instead, pour warm water into the pump to thaw it, or gently heat the exterior casing. 6. Allow the pump to naturally thaw at room temperature. Freezing and cracking of water pumps are typically caused by natural factors, so taking proper preventive measures can help minimize losses. In addition, Dayang Company plans to further expand production and sales of new-energy vehicle powertrain systems, aiming for substantial growth in both revenue and profitability. This article was reprinted and published by Shanghai Hongdong. Our company specializes in manufacturing LQRY high-temperature oil pumps, LQRY heat-transfer oil pumps, high-temperature oil pumps, gear oil pumps, and more. Please visit our official website for detailed product information. Furthermore, industry leader Jiangte Motor has adopted a comprehensive approach to the new-energy sector, starting from raw material sourcing. The company recently established a production line in Yichun, Jiangxi, capable of producing 15,000 tons per year of lithium carbonate extracted from spodumene, with trial operations expected to begin in August. Overall, the new-energy sector has emerged as a key driver of profit growth for motor manufacturers. As of May 2018, China's installed capacity of new-energy vehicle drive motors reached 90,242 units, with permanent-magnet synchronous motors accounting for nearly 90% of the market share and becoming the dominant technology. In August, Wolong Motor stated on its investor engagement platform that it has already partnered with numerous domestic and international automakers and component suppliers to develop motors for new-energy vehicles. The company aims to deliver approximately 80,000 units this year while simultaneously completing preparations for mass production among overseas customers. To date, the Ministry of Industry and Information Technology has released the latest edition of the "Recommended Model Catalog for New-Energy Vehicle Promotion and Application," which includes the fifth, sixth, seventh, and eighth batches. Statistics show these four batches collectively feature 3,057 models, with 216 enterprises supplying motors to support these vehicles. Among them, Guangxi Yuchai, Suzhou Green Control, Zhengzhou Yutong Bus, CRRC Times Electric, and Jingjin Electric rank highest in terms of motor supply volume. Notably, Guangxi Yuchai provides components for over 200 models, while the others supply motors for 172, 136, 136, and 129 models, respectively.
The regulating return valve and current of a centrifugal pump
The performance of a centrifugal pump is curve‑based and not entirely linear. The shaft power consumed by the pump depends solely on its flow rate, while the flow rate is influenced by the discharge pressure. When a centrifugal pump operates with recirculation, the discharge pressure effectively decreases, causing the flow rate to exceed the rated value and, consequently, increasing the pump’s current draw. Conversely, when you close the recirculation valve, the pump’s discharge flow diminishes, reducing the required shaft power and, in turn, lowering the motor current. Flow can be adjusted simply by regulating the discharge valve. Installing a recirculation line is primarily dictated by process requirements; in some cases, opening the recirculation valve during operation helps reduce the internal pressure within the pump, thereby minimizing stress on the mechanical seal.
2020/12/13
Causes of Insufficient Suction in Self-Priming Pumps and Troubleshooting Methods
I. A newly installed self-priming pump may lack suction; if its suction is very weak or nonexistent, possible causes include: 1. Air leakage in the inlet piping.
Common Misconceptions in Centrifugal Pump Selection and Application
I. Phenomenon: The centrifugal pump exhibits reduced flow rate and pressure. Primary causes include: ① the filter has excessively large pores, allowing impurities in the crude oil to clog the pump’s impeller suction inlet; ② improper clearance between the balance plate and balance disc, or excessive clearances in the shaft–impeller fit and between the impeller throat ring and the guide‑vane wear ring (caused by misalignment).