Causes of Leakage in Screw Pumps and Precautions


Release date:

2020/12/18

Author:

GUANGSHUO

There are several reasons why a screw pump may suddenly leak during normal operation: first, mechanical seal leakage; second, misalignment during installation; and third, wear of the shaft sleeve. The pump’s casing and liner are integrated into a single unit (collectively referred to as the pump body), with a mechanical seal serving as the shaft seal. Screw pumps come in various structural designs, typically handling small flow rates ranging from 0.2 to 6.5 m³/h. As mentioned earlier, the pump body and liner are combined into one piece, and the shaft seal is a mechanical type. The fluid being pumped moves axially in a uniform straight line within the pump, resulting in low pressure pulsation, stable flow, and reduced noise. Additionally, due to the low inertia of rotating components, the starting torque and vibration are minimal. The main causes of sudden leakage during normal operation include: cavitation, air entrainment, or prolonged pressure buildup, which can damage the seals; insufficient actual output leading to excessive internal recirculation of the medium, causing heat accumulation and subsequent vaporization that compromises the seal; excessive backflow, which stirs up sediment at the bottom of the suction-side vessel (such as a tower, kettle, tank, or pool), thereby damaging the seal; and failure to manually turn the pump by hand before restarting after extended downtime, resulting in adhesion between friction pairs and tearing of the sealing surfaces. During operation, because the two driven screws symmetrically mesh with the driving screw, all radial forces acting on the driving screw are balanced, so it does not experience bending loads. The radial forces on the driven screws are supported along their entire length by the pump cylinder liner, eliminating the need for additional bearings at the ends and virtually removing bending stresses. Furthermore, during operation, an oil film forms between the outer surface of the screws and the inner wall of the pump cylinder, preventing direct metal-to-metal contact and significantly reducing wear on the screw tooth surfaces. What aspects should be understood when using a screw pump? 1. Downhole gas separation: Ineffective pump performance is often caused by gas interference, which can be diagnosed through acoustic liquid‑level measurements and dynamometer cards. Ideally, the pump inlet should be positioned below the fluid entry zone; if placed above, a gas separator must be used. If the valve seat section is installed at least 10 feet below the bottom of the fluid entry zone, effective gas separation can occur in the annulus, with the casing functioning as the outer shell of the separator. However, well conditions frequently preclude positioning the pump below the fluid entry zone, necessitating the use of a downhole gas separator. Conventional gas separators consist of a fluid entry section (e.g., a perforated tubing section), an outer tube (typically a capped tubing section at the bottom), and a liquid‑sealing pipe at the pump base. 2. Diagnosing low‑energy effects: To diagnose this issue, determine the overall efficiency of the pumping system by measuring the input power of the prime mover, assessing the bottomhole production pressure, and collecting accurate production test data. For conventional beam‑type pumping systems, the total efficiency should ideally be around 50%; if lower, performance needs improvement. Techniques to enhance overall efficiency include maintaining high volumetric efficiency—matching pump specifications to wellbore injection rates, mitigating gas interference, and employing vacuum controllers or timers to regulate pumping—and replacing oversized electric motors. 3. Dynamometer cards measure the pump’s fill factor percentage, while integrated data acquisition systems can simultaneously capture motor power and dynamometer readings. One primary purpose of dynamometer cards is to diagnose pump operating conditions and analyze downhole issues. Combining liquid‑level measurements with dynamometer data helps determine whether the well is producing at high rates, whether the liquid column exceeds the depth of the pump inlet, whether the pump is not fully filled, and whether free gas is migrating upward through the annulus. 4. Pump displacement can be controlled by adjusting four parameters: plunger size, stroke length, pump strokes per minute, and daily operating hours. Since replacing equipment is costly, it is usually preferable to modify existing configurations rather than changing pump dimensions. A simpler approach involves reconfiguring surface equipment—for example, moving the beam linkage to alter the stroke length of both the surface and pump mechanisms—or replacing the motor pulley to adjust the number of pump strokes. Matching pump capacity to well productivity can also be achieved by modifying daily operating hours. Several devices can help control operating time, including vacuum controllers, interval timers, and percentage‑based timers. Vacuum controllers stop the pump if they detect incomplete filling, while interval timers offer a cost‑effective and easy‑to‑operate solution. The duration of pump shutdowns should be kept short enough to ensure that the bottomhole production pressure rises by no more than 10% of the reservoir pressure. Operators can allocate approximately 45 minutes per well to perform acoustic and dynamometer measurements, thereby determining well productivity, downhole pump dynamics, downhole gas separator performance, sucker rod and beam‑type pumping machine loadings, and motor status. Through this 45‑minute analysis, operators can maximize well output while reducing operational costs. 5. Acoustic liquid‑level measurements should be conducted to determine the relative depth between the liquid level and the pump inlet. If the liquid level exceeds the pump inlet, the well cannot sustain high production rates. When gas interference affects yield, the liquid level will be higher than the pump inlet; conversely, if excessive pumping leads to low production, the liquid level should be at or near the pump inlet.

Sudden leakage during normal operation of a screw pump can be attributed to several causes: first, mechanical seal failure; second, misalignment during installation; and third, wear of the shaft sleeve. The pump’s casing and liner are integrated into a single unit (collectively referred to as the pump body), with a mechanical seal serving as the shaft seal. Screw pumps come in various structural configurations; typically, they handle small flow rates ranging from 0.2 to 6.5 m³/h. In these pumps, the casing and liner form an integral assembly (referred to as the pump body), and the shaft seal is a mechanical type. The fluid being pumped undergoes uniform axial linear motion within the pump, resulting in low pressure pulsation, stable flow, and reduced noise. Moreover, due to the low inertia of rotating components, the starting torque and vibration are minimal. The primary reasons for sudden leakage during normal operation include: dry running, cavitation, or prolonged over‑pressurization, which can damage the seal; insufficient actual output, leading to extensive internal recirculation of the fluid, heat buildup, and subsequent vaporization that compromises the seal; excessive backflow, causing sediment at the bottom of the suction-side vessel (tower, kettle, tank, or sump) to resuspend and erode the seal; and extended periods of shutdown followed by restart without manual turning of the rotor, which can cause the friction pair to seize and tear the sealing surfaces.
When a screw pump is in operation, the two driven screws mesh symmetrically with the driving screw, thereby fully balancing the radial forces acting on the driving screw and eliminating bending loads on it. The radial forces experienced by the driven screws are supported along their entire length by the pump liner; consequently, no additional bearings are required at the outer ends, and these screws are essentially free from bending loads as well. During operation, an oil film forms between the outer surface of the screws and the inner wall of the pump casing, preventing direct metal-to-metal contact and significantly reducing wear on the screw tooth surfaces.
What aspects should be understood when using a screw pump?
1. Downhole Gas Separation: Ineffective pump operation is often caused by gas interference and can be diagnosed using acoustic‑based liquid‑level measurements and dynamometer cards. Ideally, the pump suction should be positioned below the fluid‑entry zone; if it must be above, a gas separator should be employed. When the valve‑seat sub is installed at least 10 ft below the bottom of the fluid‑entry zone, effective gas separation can occur in the annulus, with the casing serving as the outer shell of the separator. However, well conditions frequently preclude placing the pump below the fluid‑entry zone, in which case a downhole gas separator should be considered. A conventional gas separator consists of a fluid‑entry section (such as a perforated sub), an outer barrel (e.g., a tubing section with a plug at the bottom), and a liquid‑seal pipe at the pump bottom.
2. Diagnosis of the low‑efficiency effect: The diagnostic approach involves determining the overall system efficiency, which can be assessed by measuring the power input to the prime mover, monitoring bottomhole production pressure, and utilizing accurate production test data. For conventional beam‑type pumping systems, the overall efficiency should typically be around 50%; if it falls below this level, performance should be improved. Techniques for enhancing overall efficiency include maintaining a high volumetric efficiency—by matching pump specifications to wellbore injection rates, mitigating gas interference, and employing vacuum controllers or timers to regulate pumping operations—and replacing oversized electric motors.
3. The pump fill factor, expressed as a percentage, is determined using a dynamometer. With an integrated data acquisition system, motor power and dynamometer data can be obtained simultaneously. One of the primary purposes of a dynamometer card is to diagnose pump operating conditions and analyze downhole issues. By combining production‑level measurements with dynamometer data, it is possible to assess whether the well is producing at a high rate, whether the liquid column height exceeds the pump suction depth, whether the pump is not fully filled, and whether free gas is migrating upward through the annulus between the casing and tubing.
4. Pump displacement can be controlled by adjusting four parameters: plunger size, stroke length, pump strokes per minute, and daily operating time. Since pulling the equipment out of the well is costly, pumps with unsuitable dimensions are typically not replaced. A simpler approach is to modify surface‑equipment configurations—for example, repositioning the beam and connecting rod to adjust the stroke length of both the surface unit and the pump. Alternatively, changing the motor pulley size can regulate the pump’s stroke rate. Matching pump capacity to well production can also be achieved by adjusting the daily operating time; several devices can be used for this purpose, including empty‑pump controllers, interval timers, and percentage‑based timers. An empty‑pump controller stops the pump when it detects that the pump is not fully primed. Timers control the pump’s operating duration; they are relatively inexpensive and easy to operate. The shutdown period should be short enough so that the bottomhole flowing pressure rises by no more than 10% of the reservoir pressure. Operators can perform the aforementioned acoustic‑wave and dynamometer tests on each well for about 45 minutes to determine the well’s production capacity, downhole pump dynamics, downhole gas‑separator performance, sucker‑rod and beam‑pump loads, and motor characteristics. Through this 45‑minute analysis, operators can maximize well output while reducing operating costs.
5. Sonic‑based liquid‑level measurements should be conducted to determine the relative depth of the fluid level with respect to the pump suction inlet. If the liquid level is higher than the pump suction inlet, the well cannot be produced at a high rate. If gas interference is reducing production, the liquid level will be above the pump suction inlet; if excessive pumping rates are causing low production, the liquid level should be at or near the pump suction inlet.