Common Misconceptions in Centrifugal Pump Selection and Application


Release date:

2020/12/13

Author:

GUANGSHUO

I. Phenomenon: The centrifugal pump exhibits reduced flow rate and pressure. Primary causes include: ① the filter has excessively large pores, allowing impurities in the crude oil to clog the pump’s impeller suction inlet; ② improper clearance between the balance plate and balance disc, or excessive clearances in the shaft–impeller fit and between the impeller throat ring and the guide‑vane wear ring (caused by misalignment).

Fault Diagnosis and Maintenance of Multistage Centrifugal Pumps


I. Phenomenon: The centrifugal pump’s flow rate and pressure decrease.


Main reasons:
① The filter has excessively large pores, and impurities in the crude oil are clogging the pump’s impeller suction inlet.
② Improper clearance between the balance plate and the balance disk, as well as excessive clearance in the fits between the shaft and the impeller, and between the impeller shroud ring and the guide vane wear ring (caused by misalignment).
③ Impeller damage (wear‑induced damage, cavitation damage, manufacturing quality);
④ A rupture or leak in the oil inlet pipeline has disrupted the supply‑delivery relationship.


Handling method:
① Open the low-pressure side of the pump and remove any debris lodged inside the impeller.
② Start the centrifugal pump, and use a dial caliper and inside/outside calipers to check the fit clearance. During installation, adhere to the specified installation requirements.
③ Carefully inspect the impeller’s wear surface; analyze the cause of damage and develop a plan for the next steps (pump operating conditions vary, so do not apply rigid, one-size-fits-all procedures).
④ Inspect the oil inlet pipeline and associated equipment;


II. Phenomenon: After starting the pump, oil delivery initially proceeds normally, but the pressure subsequently declines gradually.


Main reasons:
① The filter is too dirty, impeding oil flow;
② Oil temperature too high (cavitation) or too low (oil viscosity too high);
③ Blockage of the balance pipe (can be checked by hand) causes overheating in the high-pressure section of the pump head, thereby affecting the head.
④ Incomplete venting allows air bubbles to gradually accumulate during oil transfer, forming gas slugs that impede liquid entry into the pump.
⑤ After tank emptying, pressure changes within the pipeline cause dissolved gas to come out of solution, thereby affecting the oil‑transport environment.


Handling method:
① Stop the pump and clean the filter;
② Control the oil temperature;
③ Remove the balance pipe and clear any blockages;
④ Completely vent the system (During the initial oil‑pumping phase, perform frequent checks, closely monitor pressure gauge needle fluctuations, and promptly vent any air trapped in the pump).
⑤ Vent the gas slug caused by tank-to-tank transfer (it is recommended to redesign the oil pipeline by separating the inlet line of the buffer tank from the main tank’s oil pipeline upstream of the filter);


3. Phenomenon: During operation, the centrifugal pump’s balance disc wears down, and the pump’s axial displacement exceeds the specified limit.


Main reasons:
① The pump is not delivering sufficient flow, and excessive impurities in the oil are causing wear on the pump’s balance disc.
② Improper assembly results in an excessive or insufficient allowable shaft float.
③ Bearing wear increases the clearance, resulting in excessive axial play.
④ Improper operation: failing to adjust (open) the clearance between the balance disc and the balance plate each time the centrifugal pump is started.
⑤ Misalignment between the motor shaft and the pump shaft (resulting in radial and axial runout) causes a series of mechanical damages, leading to excessive clearance between the balance disc and the balance plate.


Handling method:
① Stop the pump, replace the balance disc, and adjust the balance clearance.
② Readjust the assembly clearance;
③ Replace the bearing;
④ Determine the correct operating procedure;
⑤ Adjust the equipment’s concentricity.


4. Phenomenon: After starting the pump, the pump pressure drops and the pump fails to deliver flow.


Main reasons:
① Incomplete priming; air remains in the pump.
② Filter or oil inlet line blockage (causing poor oil flow), and blockage at the inlet of the primary impeller;
③ Oil temperature too low or too high;
④ The liquid level (or pressure) in the surge drum or buffer tank is too low;
⑤ Severe wear of the balancing device (caused by blockage of the balance pipe or improper operation);
⑥ Leakage at the low-pressure side of the centrifugal pump allows air to enter the pump.


Handling method:
① Re‑vent until the liquid flows out naturally from the outlet drain valve;
② Clean the filter or inspect the diameter of the oil inlet pipeline;
③ It is advisable to maintain the oil‑transfer temperature within the range of 450°C to 500°C.
④ Check the liquid level and pressure of the oil transfer tank and the buffer tank.
⑤ Inspect the balancing device (open it for inspection if necessary);
⑥ Inspect and replace the low-pressure-side seal of the centrifugal pump, or adjust the gland nut screw.


5. Phenomenon: During operation, the balance pipe and the high-pressure end of the centrifugal pump become excessively hot, and the pump discharge pressure drops.


Main reasons:
① The balancing mechanism has lost its function, and dry friction between the balance plate and the balance disc is causing poor heat dissipation.

② Bearing damage (due to poor lubrication conditions) causes the pump head temperature to rise.
③ Misalignment of the equipment leads to uneven wear on the seals and bearings in the high-pressure section.
④ If the packing seal is too tight and the allowable leakage is excessively low, the pump discharge may overheat.


6. Phenomenon: During operation, the balance pipe and the high-pressure side of the centrifugal pump become excessively hot, and the pump discharge pressure drops. The primary causes are:


① The balancing mechanism has lost its function, and dry friction between the balance plate and the balance disc is causing poor heat dissipation.
② Bearing damage (due to poor lubrication conditions) causes the pump head temperature to rise.
③ Misalignment of the equipment leads to uneven wear on the seals and bearings in the high-pressure section.
④ If the packing seal is too tight and the allowable leakage is excessively low, the pump discharge may overheat.


Handling method:
① Inspect and replace the balance board, and correct the operating procedure.
② Inspect and replace the high- and low-pressure end bearings, and perform regular maintenance (improve lubrication conditions;
③ Adjust concentricity;
④ Inspect the shaft sleeve for severe wear, and assess the sealing conditions (material quality and installation method) before replacing the packing with new material.