Causes of Insufficient Suction in Self-Priming Pumps and Troubleshooting Methods
Release date:
2020/12/13
Author:
GUANGSHUO
I. A newly installed self-priming pump may lack suction; if its suction is very weak or nonexistent, possible causes include: 1. Air leakage in the inlet piping.
I. The newly installed self-priming pump has no suction.
Possible reasons why a newly installed self-priming pump has very weak suction or no suction at all are:
1. Caused by air leakage in the inlet pipeline.
2. Caused by the installation of an inlet pipe that is too large and too long.
3. The reason why water was not added to the pump chamber.
4. This is due to the self-priming pump motor running in reverse.
If the issue is a gas leak in the pipeline, you can perform a pressure‑test or a vacuum‑test. For flexible hoses, install end caps at both ends of the hose, connect a three‑way fitting to the middle of the evacuation line, and attach a ball valve and a vacuum gauge; then use a vacuum pump to conduct a negative‑pressure test. Once the vacuum has been reduced to its maximum allowable level, close the ball valve in the middle of the evacuation line and observe whether the vacuum gauge reading drops. Users often remove the inlet of a self‑priming pump and place their hand near the inlet to sense the suction force and try to pinpoint the problem. However, this testing method is incorrect. Conventional self‑priming centrifugal pumps do not generate strong suction quickly; they can only gradually evacuate the air from a completely sealed pipeline until a certain degree of negative pressure is achieved, at which point liquid can be drawn up. Once the inlet pipe is disconnected, no reliable suction can be detected. If the pump fails to prime because the suction lift is too high or the suction line is excessively long, consider using a self‑priming pump with a higher suction lift capability.
II. What is the reason why a self-priming pump has no suction at all under normal operating conditions?
If a normally operating self-priming pump suddenly loses its suction, check the pump chamber and impeller for blockages. Before servicing, disconnect power and close the inlet and outlet valves. Open the drain plug on the pump body to completely drain the water from the chamber, remove the motor base mounting bolts, and separate the coupling. For direct‑drive motors, also loosen the base mounting bolts. Then, unscrew the bolts around the pump cover to extract the bearing housing and impeller as a unit. Once removed, inspect the impeller for any debris or obstructions.
关键字:
Leave a Message Online
*Note: Please ensure that all information provided is accurate and keep your contact details up to date. We will get in touch with you as soon as possible.